E17
Electrolux
Tank Level Sensor / Probe Error
Display shows E17; unit may not fill or may show abnormal tank level (for models with level sensor)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Scaled or corroded level probes, Loose level sensor wiring, Faulty electronic level sensor, Incorrect grounding of tank
How to Fix / Troubleshooting
Safety first: Turn OFF power and close water supply. Relieve pressure before removing any probes.
Steps:
- 1. Locate level sensor: On models with electronic level control, find the level probes or sensor assembly on the tank.
- 2. Clean probes: Remove mineral deposits from metal probes using a non-abrasive pad and descaling solution. Rinse thoroughly.
- 3. Check wiring: Ensure all level sensor wires are firmly connected and not damaged.
- 4. Verify tank ground: Confirm that the tank is properly grounded as per installation instructions; some level systems rely on tank ground reference.
- 5. Replace sensor: If cleaning and wiring checks do not resolve E17, replace the level sensor assembly.
Professional help: If the control board still reports level errors after sensor replacement, PCB diagnostics are required.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Tank Level Sensor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements