A05
Fondital Fan / Air Pressure Switch Fault

Error A05 appears, fan may run continuously or not at all, burner does not ignite.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective fan motor, Blocked air pressure switch tubing, Faulty air pressure switch, Blocked flue or condensate trap (on condensing models)

How to Fix / Troubleshooting

Safety: Isolate electrical power before touching internal components.

  • Check flue and condensate: Ensure the flue terminal is clear. On condensing Fondital models, inspect the condensate trap and drain hose for blockage; clean and flush with water if necessary.
  • Inspect fan: Remove the front cover and visually inspect the fan wheel for dirt buildup or foreign objects. Spin the fan gently by hand (power OFF) to check for free movement.
  • Air pressure switch tubing: Remove the silicone tubes from the air pressure switch and fan connections. Check for water, kinks, or blockages; blow through gently to clear.
  • Test fan start: Restore power and call for heat while observing the fan. If it does not start or is very noisy, the fan assembly or its capacitor is likely faulty and should be replaced.
  • Pressure switch: If the fan runs but A05 persists, the air pressure switch may not be closing. This requires electrical testing and likely replacement by a technician.