A06
Fondital
Ignition Control / Flame Signal Instability
Display shows A06, burner shuts down, often associated with ignition noise or delayed ignition.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Incorrect electrode gap or position, Poor burner grounding, Faulty ignition transformer on control board, Damaged ignition cable
How to Fix / Troubleshooting
Safety: Turn off gas and power before adjusting electrodes.
- Inspect ignition and ionization electrodes: Check for cracks in ceramic insulators, burnt tips, or carbon tracking. Replace if damaged.
- Adjust electrode gap: Using the Fondital service manual, set the correct distance between ignition electrode and burner surface. Ensure the ionization electrode is fully in the flame path.
- Check grounding: Verify that the burner and chassis earth connections are tight and free of corrosion. Poor grounding can cause unstable flame detection.
- Ignition cable: Inspect the high‑voltage cable for cuts or burn marks. Replace if insulation is compromised.
- Control board: If all mechanical parts are correct and A06 persists, the ignition circuit on the electronic control board may be defective and should be tested and replaced by a qualified technician.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Ignition Cable
Check Price on Amazon
We may earn a commission from links on this page.