A09
Fondital Flow Switch / DHW Flow Sensor Fault

Display shows A09, unit refuses to start, often after a power outage or wiring work.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck DHW flow switch, Faulty Hall-effect flow sensor, Wiring fault between sensor and control board, Blocked inlet filter

How to Fix / Troubleshooting

Safety: Disconnect power and close water supply before removing any water connections.

  • Check DHW demand: Open a hot tap and observe if the flow indicator on the display (if available) activates. If not, the flow sensor may not be detecting flow.
  • Clean inlet filter: At the cold water inlet of the Fondital heater, remove and clean any mesh filter to restore proper flow.
  • Inspect flow sensor: Locate the DHW flow sensor or flow switch body. Remove it carefully and check for debris or scale that may prevent movement of the internal turbine or paddle. Clean and reinstall with new seals if needed.
  • Check wiring: Ensure the sensor connector is firmly seated on the control board and that cables are not damaged.
  • Replace sensor: If A09 persists and wiring is sound, replace the DHW flow sensor with a compatible Fondital part.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

DHW Flow Sensor
Check Price on Amazon