A10
Fondital
Primary NTC Sensor Fault (Flow Temperature Sensor)
Error A10, unit may start but then shut down, sometimes with fluctuating temperature readings.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted NTC sensor, Loose sensor connection, Damaged sensor cable, Faulty control board input
How to Fix / Troubleshooting
Safety: Turn off power before accessing the control board or sensors.
- Locate primary NTC: Find the flow temperature sensor clipped to the primary heat exchanger outlet pipe.
- Check connection: Ensure the plug is fully inserted into the sensor and the control board. Look for corrosion or moisture on the contacts.
- Inspect cable: Follow the cable for cuts, pinches, or burn marks. Replace if damaged.
- Sensor replacement: If the sensor body is cracked or readings are clearly wrong (e.g., showing very high or low temperature when cold), replace the NTC sensor with the correct Fondital spare.
- Control board: If a new sensor does not resolve A10, the temperature input circuit on the control board may be defective and requires professional replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Primary NTC Temperature Sensor