A16
Fondital
Room Thermostat / External Control Fault
Error A16, unit may not respond to thermostat or user commands.
Advertisements
Possible Causes
Open circuit in room thermostat wiring, Incorrect thermostat settings, Faulty external control module, Misconfigured control parameters
How to Fix / Troubleshooting
Safety: Turn off power before altering low‑voltage control wiring.
- Check thermostat: Ensure the room thermostat or remote control is powered, set to heating mode, and calling for heat.
- Inspect wiring: At the Fondital terminal strip, verify that thermostat wires are firmly connected and not broken.
- Bypass test: Temporarily bridge the thermostat terminals at the heater (if allowed by the manual). If the unit starts, the thermostat or its wiring is faulty.
- External module: If using an OpenTherm or proprietary Fondital controller, check its display for errors and reset it according to its manual.