A19
Fondital
Fan Speed / Tachometer Fault
Display shows A19, often with irregular fan speed or noise.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective fan tachometer sensor, Loose fan connector, Obstructed fan wheel, Control board fan driver fault
How to Fix / Troubleshooting
Safety: Disconnect power before touching the fan.
- Inspect fan wheel: Remove the cover and check for dust buildup or foreign objects in the fan. Clean carefully.
- Check connector: Ensure the multi‑pin fan connector is fully seated on both fan and control board.
- Spin test: With power OFF, spin the fan by hand to ensure it moves freely without grinding.
- Replacement: If the fan does not reach commanded speed or tachometer feedback is missing, replace the fan assembly. If the issue persists, the control board may be defective.
Advertisements
Repair Difficulty
Hard
4/5