Possible Causes

Incorrect gas/air ratio, Partially blocked burner ports, Loose flue components, Fan speed out of calibration

How to Fix / Troubleshooting

Safety: Noise may indicate combustion issues; have it checked promptly.

  • Visual inspection: Check that the flue is properly assembled and all joints are tight.
  • Burner cleaning: Clean burner ports to remove deposits that can cause whistling.
  • Combustion setup: A technician should check CO₂/O₂ levels and adjust gas valve and fan speed parameters according to Fondital guidelines.