Possible Causes
Tripped breaker, tripped upper thermostat ECO, failed upper heating element, loose line connections at junction box
How to Fix / Troubleshooting
Safety: Turn OFF the breaker before opening any covers.
Steps to troubleshoot no hot water:
- Check breaker: Verify the water heater breaker is ON and not tripped. Reset if necessary.
- Reset ECO: Remove the upper access panel and press the red reset button on the upper thermostat until it clicks.
- Inspect wiring: At the top junction box, ensure all wire nuts are tight and no wires are burned.
- Test upper element: With power off, test resistance across the upper element. Replace if open.
- Restore power and test: After any repairs, restore power and allow several hours for water to heat.