F3
Giant Pressure Switch / Air Proving Fault

F3 displayed, fan runs but no ignition on power‑vent gas model

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked intake or exhaust vent, Failed pressure switch, Disconnected or cracked pressure tubing, Condensate blockage in vent

How to Fix / Troubleshooting

Safety first: Turn off power and gas. Do not operate the heater with a suspected venting problem.

  • Inspect venting: Check the entire length of the Giant power‑vent intake and exhaust pipes for obstructions, snow, nests, or debris. Clear any blockage.
  • Check condensate drain: If the unit is condensing, ensure the condensate trap and drain line are not clogged or frozen.
  • Examine pressure tubing: Verify the small rubber tube from the blower housing to the pressure switch is securely connected and not cracked or kinked.
  • Test pressure switch: With a multimeter, check continuity across the pressure switch terminals when the blower is running. If it does not close, replace the Giant pressure switch.
  • Control diagnosis: If the switch operates correctly but F3 remains, the control board input may be faulty and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Giant Air Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements