06
Immergas Domestic Hot Water (DHW) Temperature Sensor Fault

Error 06 appears; water temperature on the display is unrealistic (very high or very low) and burner does not operate correctly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW NTC sensor, Loose DHW sensor clip on outlet pipe, Wiring harness damage, Scale buildup isolating sensor from water flow

How to Fix / Troubleshooting

Safety: Disconnect power and close the cold water inlet valve before removing any DHW components.

  • Locate DHW NTC: The DHW sensor is usually on the hot water outlet pipe or integrated into a DHW manifold on Immergas water heaters.
  • Check mounting: Ensure the sensor is firmly clipped to the pipe or inserted fully into its pocket. A loose sensor can misread temperature.
  • Inspect wiring: Follow the cable back to the control board, checking for damage or loose connectors.
  • Descale outlet section (if accessible): If the outlet pipe is heavily scaled, temperature transfer to the sensor may be delayed. Consider descaling the DHW circuit using a pump and approved descaling solution, or have a technician perform this.
  • Replace DHW NTC: If readings are clearly wrong, install a new Immergas DHW NTC sensor.

Note: Incorrect DHW temperature sensing can cause scalding or lukewarm water; verify operation carefully after repair.