10
Immergas
High System Pressure / Pressure Sensor Range Error
Error 10; unit indicates overpressure or abnormal pressure reading in the primary circuit.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overfilled system, Failed expansion vessel (no air charge), Blocked connection to pressure sensor, Faulty pressure sensor
How to Fix / Troubleshooting
Safety: Let the system cool. High pressure can cause hot water discharge from the safety valve.
- Check pressure gauge: If pressure is above the recommended limit (e.g., >2.5–3 bar), carefully bleed water from a radiator or drain point to reduce pressure.
- Test expansion vessel: With the system depressurized, check the air charge at the expansion vessel Schrader valve using a tire gauge. If no air or water comes out, the vessel may be failed and should be replaced or recharged to the specified pressure.
- Inspect pressure sensor: Ensure the sensor port is not blocked by sludge. Clean or replace as needed.
- Reset and monitor: After correcting pressure, reset the unit and monitor for recurring pressure rise, which indicates an expansion vessel or filling loop issue.
Note: Expansion vessel replacement is typically a technician task due to system draining and re‑commissioning requirements.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Expansion Vessel
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements