Possible Causes
Minimum burner power too high for demand, Scaled heat exchanger causing rapid temperature rise, Incorrect flow sensor calibration, Very low flow at tap
How to Fix / Troubleshooting
Safety: Turn off power and gas before internal work.
- Increase flow: Open the hot tap more fully to increase flow and reduce cycling.
- Descale heat exchanger: Remove scale from the primary and DHW plate heat exchangers to improve heat transfer and reduce rapid overheating.
- Service settings: Have a technician check minimum burner modulation and DHW parameters.
Note: Some cycling at very low flows is normal; persistent rapid cycling at normal flows indicates a fault.