Kospel Keypad / Control Panel Malfunction

Display is on but buttons do not respond or respond intermittently.

Advertisements

Possible Causes

Worn or damaged keypad membrane, Moisture behind control panel, Loose ribbon cable to main PCB, Faulty user interface PCB

How to Fix / Troubleshooting

Safety: Disconnect power before removing the front panel.

  • 1. Dry and clean: Check for condensation or water ingress around the display and buttons. Dry thoroughly and identify any leak paths.
  • 2. Reseat cable: Disconnect and reconnect the ribbon cable between the control panel and main board.
  • 3. Inspect keypad: If certain buttons never work, the keypad membrane or PCB is likely faulty. Replace the entire control panel assembly.