E14
Kospel Internal Power Supply Fault

Heater shows E14; unit may not respond or may reboot repeatedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed low-voltage power supply on main PCB, Short circuit on control electronics, Damaged transformer or SMPS components, Overloaded accessory circuit

How to Fix / Troubleshooting

Safety: Disconnect power and wait for capacitors to discharge before touching the PCB.

  • 1. Visual inspection: Remove the cover and inspect the main PCB for burned components, bulging electrolytic capacitors, or cracked solder joints.
  • 2. Check for shorts: Disconnect any optional accessories (e.g., external control modules) and see if E14 clears.
  • 3. Board replacement: Internal power supply faults are not typically field-repairable. Replace the main control board with a genuine Kospel part.
  • 4. Verify supply: After replacement, confirm that mains voltage and wiring are correct to avoid repeat failures.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Main Control Board
Check Price on Amazon