E19
Kospel Excessive Temperature Rise / Delta-T Fault

Display shows E19; heater may limit power or shut down under high temperature rise.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Severely scaled heat exchanger, Flow rate below design, Incorrect power configuration, Faulty temperature sensing causing miscalculation

How to Fix / Troubleshooting

Safety: Disconnect power and allow the heater to cool before servicing.

  • 1. Check flow rate: Confirm that the water flow meets Kospel’s minimum for the selected power. Clean inlet filters and open valves fully.
  • 2. Descale heat exchanger: In hard-water areas, perform a chemical descaling of the heat exchanger following Kospel’s procedure, or replace the exchanger if heavily blocked.
  • 3. Verify power setting: Ensure the heater’s configured power does not exceed the available flow and installation design.
  • 4. Sensor check: Confirm inlet and outlet NTC sensors are accurate and correctly installed; replace any faulty sensors.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Heat Exchanger / NTC Sensors
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements