Possible Causes
Incorrect sensor placement, Mixed hot and cold water downstream, Faulty thermostatic mixing valve, Calibration drift of NTC sensors
How to Fix / Troubleshooting
Safety: Use a thermometer to avoid scalding when checking actual water temperature.
- 1. Measure at outlet: Measure water temperature directly at the heater outlet if possible, then at the tap. Differences indicate mixing or losses in piping.
- 2. Check mixing valves: Inspect and adjust or replace any thermostatic mixing valves installed after the heater.
- 3. Sensor placement: Ensure the outlet NTC is firmly attached to the outlet pipe or in its designated well.
- 4. Replace sensors: If calibration is suspect, replace the NTC sensors with genuine Kospel parts.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outlet NTC Sensor / Mixing Valve