Kospel
No Power / Dead Unit
Water heater does not turn on at all; no display, no lights, no response.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Tripped circuit breaker or blown fuse, Loose supply wiring at Kospel terminal block, Faulty main power switch on heater, Defective main control board power supply
How to Fix / Troubleshooting
Safety: Work on mains circuits only if you are qualified. Always turn off the main breaker before opening the heater.
- 1. Check external protection: Verify that the dedicated breaker or fuse for the Kospel heater is ON and not tripped. Reset or replace if necessary, but investigate why it tripped.
- 2. Inspect supply voltage: Using a multimeter, confirm that correct voltage is present at the heater’s supply terminals (only if you are competent to do so safely).
- 3. Tighten terminals: With power off, remove the terminal cover and check that all supply wires are firmly clamped.
- 4. Main switch: If your model has a built-in power switch, test it for continuity. Replace if it does not pass power when switched on.
- 5. Control board: If supply is present but the display remains dark, the internal low-voltage power supply on the main PCB may have failed. Replace the main control board.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control Board / Power Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements