E007
Lochinvar
Outlet Water Temperature Sensor Fault
Lochinvar heater shows E007; unit may run briefly then shut down.
Advertisements
Possible Causes
Open or shorted outlet temperature sensor, Loose sensor connection, Damaged wiring harness
How to Fix / Troubleshooting
Safety: Disconnect power before working on sensors or wiring.
Steps:
- 1. Access outlet sensor: Locate the outlet temperature sensor on the hot water outlet pipe.
- 2. Check connections: Ensure the sensor plug is fully seated on the sensor and at the control board. Look for corrosion or moisture at the connector.
- 3. Measure resistance: With the sensor unplugged, measure resistance and compare to Lochinvar's specified values for the current water temperature. Replace the sensor if readings are out of range.
- 4. Inspect harness: Follow the harness from the sensor to the control, checking for pinched or damaged sections. Replace the harness if insulation is compromised.
- 5. Reset and test: Restore power, clear the error, and verify stable operation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Outlet Temperature Sensor
Check Price on Amazon