E010
Lochinvar
High Limit Switch Trip / Manual Reset Limit Open
Lochinvar water heater shows E010 and shuts down; may occur during high demand.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Overheating due to failed circulation, Scale buildup on heat exchanger, Faulty high limit switch, Loose wiring to limit switch
How to Fix / Troubleshooting
Safety: The high limit indicates an overheat condition. Allow the unit to cool completely. Turn off power and close the gas valve before servicing.
Steps:
- 1. Locate high limit: Find the manual reset high limit switch on the tank or heat exchanger outlet. It usually has a red reset button.
- 2. Reset once: Press the reset button firmly until it clicks. Do not repeatedly reset without finding the cause of overheating.
- 3. Check circulation: Ensure any system or recirculation pumps are operating and that valves are open. A failed pump can cause localized overheating.
- 4. Inspect for scale: If the heater is older or in a hard water area, schedule a professional descaling of the heat exchanger and inspection of tank surfaces.
- 5. Verify wiring: Confirm that wires to and from the high limit are tight and not heat-damaged.
- 6. Replace if nuisance tripping: If the high limit trips at normal temperatures, replace it with the correct Lochinvar high limit switch and verify operating temperatures with a thermometer.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
High Limit Switch
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements