E020
Lochinvar
Pump Output / Recirculation Pump Fault
Lochinvar heater shows E020; may be associated with recirculation pump not running.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed recirculation pump, Seized pump impeller, Loose pump wiring, Control board pump relay failure
How to Fix / Troubleshooting
Safety: Turn off power and close isolation valves before removing any pump. Hot water can cause burns.
Steps:
- 1. Listen and feel for pump operation: On a call for recirculation, the pump should hum and vibrate slightly. If silent, proceed with checks.
- 2. Check electrical connections: Verify the pump is wired correctly to the Lochinvar pump terminals and that connections are tight.
- 3. Free a stuck impeller: Close isolation valves, remove the pump motor from the housing, and attempt to spin the impeller shaft with a screwdriver. If seized, replace the pump.
- 4. Test voltage: With power on and a call for recirc, measure voltage at the pump terminals. If no voltage is present, the control board relay may be faulty and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Recirculation Pump