Lochinvar Anode Rod Depletion / Localized Corrosion

Lochinvar water heater shows signs of rust around the anode rod port or hot outlet connection.

Advertisements

Possible Causes

Anode rod fully consumed, Aggressive water chemistry, Lack of maintenance inspections

How to Fix / Troubleshooting

Safety: Turn off power or gas and allow the tank to cool. Relieve pressure by opening a hot water tap before removing the anode.

Steps:

  • 1. Inspect anode rod: Remove the anode rod from the top of the tank. If it is less than 1/4 inch thick or heavily pitted, replace it.
  • 2. Clean threads and port: Remove rust from the anode port threads and apply pipe sealant to the new anode rod threads.
  • 3. Install new anode: Install a Lochinvar-compatible anode rod (magnesium or aluminum/zinc depending on water quality).
  • 4. Schedule maintenance: Plan to inspect the anode every 2–3 years to prevent future corrosion.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Anode Rod
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements