Water is warm but not hot enough even when the Navien setpoint is at maximum; no error code displayed.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety: Avoid setting temperatures above safe levels (typically 120–125°F / 49–52°C) to prevent scalding.
Steps:
- 1. Verify set temperature: Check the Navien front panel or remote controller to confirm the DHW setpoint. Ensure any child-lock or max-temp limit settings are not restricting temperature.
- 2. Check for crossover: Turn OFF the cold water supply to the Navien. Open a hot water tap; if water still flows strongly, there is a crossover (e.g., faulty single-handle faucet or mixing valve) allowing cold water into the hot line. Identify and repair the offending fixture.
- 3. Descale heat exchanger: If the unit is older or in a hard water area, flush the heat exchanger to restore full heating capacity.
- 4. Check flow rate: Extremely high flow (multiple fixtures) may exceed the unit's capacity; reduce simultaneous demand and see if temperature improves.
If water remains lukewarm after these steps, the outlet thermistor or gas valve modulation may require professional diagnosis.