A05
Nibe Return Temperature Sensor Fault

Display shows A05; water heater stops and may indicate return temperature sensor fault.

Advertisements

Possible Causes

Defective return line NTC sensor, sensor wiring shorted or open, connector corrosion at control board, sensor not properly inserted in pipe pocket

How to Fix / Troubleshooting

Safety first: Turn off power before touching any wiring or sensors.

The return temperature sensor monitors the temperature of water returning from the heating circuit or coil.

  • Step 1 – Locate sensor:
    • Find the sensor clipped to the return pipe or inserted into a sensor pocket on the return connection of the Nibe cylinder.
  • Step 2 – Check mounting:
    • Ensure the sensor is firmly attached to the pipe with thermal paste or in good contact with the pocket.
    • Re-secure any loose clips or insulation around the sensor.
  • Step 3 – Inspect wiring:
    • Follow the cable back to the control board, checking for damage or pinched sections.
    • Disconnect and reconnect the plug to clean contacts.
  • Step 4 – Test and reset:
    • Optionally measure resistance to confirm sensor health.
    • Restore power, clear the alarm, and verify that the return temperature reading is plausible.

If the alarm returns immediately with correct wiring and a new sensor, the control board may require replacement.