Display shows A16; water heater indicates sensor short-circuit or overrange on one of the NTC inputs.
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Turn off power before working on any sensor wiring.
This alarm indicates that one of the NTC sensors is reading an unrealistically low resistance (short-circuit).
- Step 1 – Identify sensor:
- Use the alarm details or service menu to see which sensor input is affected (e.g. tank, flow, return).
- Step 2 – Inspect cable:
- Follow the cable from the control board to the sensor, looking for crushed or cut insulation.
- Check junction boxes for moisture.
- Step 3 – Disconnect and test:
- Disconnect the sensor at the board and measure resistance.
- If the reading is near 0 Ω, replace the sensor.
- Step 4 – Reset alarm:
- Reconnect or replace the sensor, restore power, and clear the alarm.
Persistent short readings with the sensor disconnected indicate a fault on the control board input.
Repair Difficulty
Required Part