A19
Nibe
Cold Inlet / Mixing Valve Sensor Fault
Display shows A19; water heater indicates sensor fault on cold water inlet or mixing valve sensor (if equipped).
Advertisements
Possible Causes
Failed NTC sensor on cold inlet, sensor not properly attached to pipe, damaged cable, incorrect sensor mapping in control settings
How to Fix / Troubleshooting
Safety first: Disconnect power before working on sensors or control wiring.
This alarm relates to the sensor used to monitor cold inlet or mixing valve temperature.
- Step 1 – Locate sensor:
- Identify the sensor on the cold inlet pipe or mixing valve body.
- Step 2 – Check attachment and insulation:
- Ensure good thermal contact and re-insulate the sensor area.
- Step 3 – Inspect wiring and test:
- Check for cable damage and reseat connectors.
- Measure resistance and compare to expected values.
- Step 4 – Reset alarm:
- Restore power, clear the alarm, and verify stable readings.
Replace the sensor if faulty; if mapping is wrong, correct the configuration in the installer menu.