A19
Nibe Cold Inlet / Mixing Valve Sensor Fault

Display shows A19; water heater indicates sensor fault on cold water inlet or mixing valve sensor (if equipped).

Advertisements

Possible Causes

Failed NTC sensor on cold inlet, sensor not properly attached to pipe, damaged cable, incorrect sensor mapping in control settings

How to Fix / Troubleshooting

Safety first: Disconnect power before working on sensors or control wiring.

This alarm relates to the sensor used to monitor cold inlet or mixing valve temperature.

  • Step 1 – Locate sensor:
    • Identify the sensor on the cold inlet pipe or mixing valve body.
  • Step 2 – Check attachment and insulation:
    • Ensure good thermal contact and re-insulate the sensor area.
  • Step 3 – Inspect wiring and test:
    • Check for cable damage and reseat connectors.
    • Measure resistance and compare to expected values.
  • Step 4 – Reset alarm:
    • Restore power, clear the alarm, and verify stable readings.

Replace the sensor if faulty; if mapping is wrong, correct the configuration in the installer menu.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Cold Inlet / Mixing Valve Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.