Possible Causes

Incorrect differential or hysteresis settings, sensor placed in wrong position, oversized heater relative to cylinder volume, faulty thermostat

How to Fix / Troubleshooting

Safety first: Avoid frequent manual power cycling; let the controller manage operation once configured.

  • Step 1 – Check settings:
    • In the installer menu, verify that the temperature differential (hysteresis) is set to a reasonable value (e.g. 5–10 °C).
  • Step 2 – Sensor placement:
    • Ensure the main tank sensor is in the correct pocket and not too close to the heater element.
  • Step 3 – Observe operation:
    • Monitor how long the heater runs before stopping; if only a minute or two, a control or sensor fault is likely.

A Nibe technician may need to adjust advanced parameters or replace a faulty thermostat/sensor to resolve short cycling.