Noritz Intermittent Ignition / Weak Spark

Noritz water heater fan runs but burner does not ignite; no error code displayed, intermittent issue.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Marginal igniter electrode, Slightly low gas pressure, Loose ignition wiring, Dirty burner surface

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas before accessing internal components.

Steps to check and correct:

  • Clean igniter and burner: Remove the igniter and burner assembly and clean carbon and dust from surfaces. Reinstall securely.
  • Inspect ignition wiring: Check for loose or corroded connectors between PCB and igniter. Reseat connectors.
  • Check gas supply: Ensure gas valves are fully open and that other gas appliances are functioning normally. If multiple appliances show issues, contact your gas supplier.
  • Professional service: If intermittent ignition continues, a technician should test igniter strength, gas valve operation, and PCB output.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Igniter Assembly
Check Price on Amazon

We may earn a commission from links on this page.