Scale Buildup / Kettling in Heat Exchanger
Noritz water heater makes loud banging or popping noises during operation.
Advertisements
Possible Causes
Heavy mineral scale on heat exchanger surfaces, High hardness water with no softening, Long intervals between maintenance, High temperature setpoint exacerbating scale
How to Fix / Troubleshooting
Safety first: Turn OFF power and gas. Allow the unit to cool before connecting hoses.
Steps to check and correct:
- Perform descaling: Connect a pump and hoses to the Noritz service valves and circulate white vinegar or approved descaling solution through the heat exchanger for 45–60 minutes, following the Noritz service instructions.
- Flush thoroughly: After descaling, flush with clean water to remove residual solution.
- Install water treatment: In hard water areas, consider a water softener or scale reduction system upstream of the heater.
- Adjust temperature: Lower the set temperature if it is unnecessarily high to reduce future scale formation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.