H19
Panasonic
Remote Controller Address / Configuration Error
Panasonic water heater shows H19; unit may not respond correctly to remote commands.
Advertisements
Possible Causes
Incorrect remote address setting, Multiple remotes with conflicting IDs, Faulty remote controller PCB, Miswired remote bus
How to Fix / Troubleshooting
Safety: Turn OFF power before changing DIP switches or wiring on the controller bus.
- 1. Check number of remotes: Ensure the number of connected remote controllers does not exceed Panasonic's specification.
- 2. Verify address settings:
- Some models require setting addresses on each remote via DIP switches or menu.
- Confirm each remote has a unique address as per the manual.
- 3. Inspect remote wiring:
- Check for correct polarity and secure connections at each remote and at the heater.
- 4. Test with a single remote:
- Disconnect additional remotes and test with only one connected to isolate the fault.
- 5. Replace faulty remote: If one remote consistently causes H19 when connected, replace that remote controller.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Remote Controller Unit
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements