F9
Protherm Overtemperature Lockout / Sensor Plausibility Error

F9 displayed, appliance locks out, may be associated with very high temperature readings

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Severely scaled heat exchanger, Pump failure (on system-connected models), NTC sensor reading out of range, Control board misreading sensor

How to Fix / Troubleshooting

Safety first: Isolate power and gas. Let the unit cool. Overtemperature conditions can damage components.

  • Check NTC readings: Compare flow and return NTC values in the diagnostic menu (if available). If one is unrealistic, test and replace that sensor.
  • Verify circulation: On models connected to a storage tank or heating circuit, ensure the circulation pump is running and valves are open.
  • Inspect for scale: If the unit is used in hard water areas, suspect scale in the primary or plate heat exchanger. Perform descaling as per Protherm instructions.
  • Reset lockout: After correcting issues, reset the lockout via the front panel or by cycling power. Monitor operation to ensure temperatures remain within normal range.

Warning: Persistent overtemperature faults without clear cause require professional diagnosis to avoid heat exchanger damage or unsafe operation.

Advertisements

Repair Difficulty

Medium 3/5