12
Ruud Flame Loss During Operation

Ruud tankless water heater displays error code 12; burner lights briefly then shuts off, causing hot water to cut out.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Unstable gas pressure, Dirty burner or flame rod, Blocked vent or inadequate combustion air, Faulty flame sensing circuit on control board

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas before servicing. Hot surfaces and gas components can be hazardous.

  • Step 1 – Check vent and air intake: Inspect both intake and exhaust terminations for obstructions. Clear any debris or ice.
  • Step 2 – Inspect burner and flame rod: Remove the front cover. Check the burner surface for rust, dust, or debris. Carefully vacuum and clean. Remove the flame rod and gently clean it with fine emery cloth to remove oxidation.
  • Step 3 – Verify gas supply stability: If other gas appliances fluctuate or go out, contact your gas supplier. Gas pressure should be checked with a manometer by a professional.
  • Step 4 – Check wiring: Ensure all connections between the flame rod and control board are tight and undamaged.
  • Step 5 – Replace flame rod or control board: If cleaning and wiring checks fail, replace the OEM Ruud flame rod. If the problem persists, the control board flame sensing circuit may require replacement by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flame Rod
Check Price on Amazon