13
Ruud Combustion / Flame Rod Signal Abnormal

Ruud tankless water heater shows error code 13; unit may shut down shortly after ignition.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Improper combustion due to incorrect gas type or pressure, Blocked or improperly installed venting, Dirty burner or heat exchanger, Faulty flame rod signal

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas. Combustion issues can lead to carbon monoxide; ensure adequate ventilation.

  • Step 1 – Confirm gas type and setup: Verify the heater is configured for the correct gas (NG or LP) and that any conversion kits were properly installed.
  • Step 2 – Inspect venting: Check that vent pipe size, length, and termination meet Ruud specifications. Look for sags, dips, or disconnections.
  • Step 3 – Clean burner and heat exchanger: Remove the burner assembly if accessible per the service manual. Vacuum dust and debris from burner ports and around the heat exchanger.
  • Step 4 – Clean flame rod: Remove and clean the flame rod with fine sandpaper. Reinstall and ensure good electrical contact.
  • Step 5 – Professional combustion analysis: If code 13 persists, a technician should perform a combustion analysis and adjust gas pressure or replace components as needed.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Burner Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements