15
Ruud Booster Fan / Secondary Fan Fault (on some models)

Ruud tankless water heater shows error code 15; unit may run at limited capacity or shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed booster fan motor, Loose booster fan wiring, Blocked venting, Control board fan driver fault

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas before servicing.

  • Step 1 – Inspect venting: Ensure vent pipes are not blocked or crushed and terminations are clear.
  • Step 2 – Check booster fan wiring: Remove the front cover and locate the booster fan (if equipped). Verify connectors are secure and wires undamaged.
  • Step 3 – Listen for fan operation: Restore power and call for hot water. If the booster fan does not run when expected, turn power OFF again.
  • Step 4 – Replace booster fan: Disconnect wiring, remove mounting screws, and install a new OEM Ruud booster fan assembly. Reassemble and test.

If the new fan does not resolve the issue, the control board may need replacement by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Booster Fan Assembly
Check Price on Amazon

We may earn a commission from links on this page.