65
Ruud
Communication / Remote Control Fault
Ruud tankless water heater shows error code 65; unit may not respond correctly to recirculation or remote commands.
Advertisements
Possible Causes
Faulty remote controller, Damaged communication cable, Incorrect wiring polarity, Control board communication circuit failure
How to Fix / Troubleshooting
Safety first: Turn OFF power before working on wiring.
- Step 1 – Check remote cable: Inspect the cable between the Ruud heater and remote controller for cuts, staples through the wire, or loose connections. Ensure polarity (+/–) is correct at both ends.
- Step 2 – Reseat connectors: Disconnect and reconnect the remote cable at the control board and remote.
- Step 3 – Test with short cable: Temporarily connect the remote using a short known-good cable near the unit. If error 65 clears, replace the original cable run.
- Step 4 – Replace remote controller: If wiring is good but the error persists, replace the OEM Ruud remote controller.
If communication issues remain, the main control board may be defective and should be serviced by a professional.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Remote Controller / Communication Cable
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements