E8
Ruud Fan Speed / Combustion Feedback Error

Tankless water heater displays E8; unit may run at reduced output or shut down.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty fan speed sensor (Hall effect sensor), Loose fan harness connection, Obstructed fan wheel, Defective main control board fan circuit

How to Fix / Troubleshooting

Safety first: Turn OFF power and gas before removing covers.

  • Step 1 – Inspect fan harness: Remove the front cover and locate the combustion blower. Check the small multi-wire connector from the fan to the control board. Reseat it firmly.
  • Step 2 – Check for obstructions: Inspect the fan wheel for debris or damage. Ensure it spins freely by hand.
  • Step 3 – Reset and test: Restore power and gas, then run hot water. If E8 returns, the fan sensor or board may be faulty.
  • Step 4 – Replace fan assembly: Many Ruud fan speed sensors are integrated into the blower. With power and gas OFF, remove the blower assembly and install a new OEM Ruud combustion blower. Reconnect wiring and reassemble.

If a new blower does not resolve the issue, the main control board likely needs replacement by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Combustion Blower Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements