LED_FLASH_2
Ruud Pressure Switch / Vent Safety Fault (power vent models)

Ruud gas water heater status light flashes 2 times every 3 seconds; burner does not light.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blocked vent or intake, Failed pressure switch, Loose pressure tubing, Faulty blower motor

How to Fix / Troubleshooting

Safety first: Disconnect power and turn gas OFF. Venting issues can cause carbon monoxide hazards.

  • Step 1 – Inspect venting: Check the vent and intake pipes from the Ruud power vent heater to the termination. Remove any obstructions and ensure proper slope and support.
  • Step 2 – Check pressure tubing: Remove the blower access panel. Inspect the rubber tubing from the blower to the pressure switch for cracks, kinks, or disconnections. Reattach or replace as needed.
  • Step 3 – Test blower operation: Restore power (gas still OFF) and call for heat. Listen for the blower. If it does not run, the blower or control may be faulty.
  • Step 4 – Replace pressure switch: If the blower runs but the code persists, replace the OEM Ruud pressure switch. Disconnect wires and tubing, remove mounting screws, and install the new switch.

If problems continue, a technician should test the blower motor and control board.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Draft Inducer Pressure Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements