LED_FLASH_3
Ruud Flammable Vapor Sensor / Lockout Indication (alternate pattern)

Ruud gas water heater status light flashes 3 times every 3 seconds; burner will not light.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Triggered flammable vapor sensor, Failed FVS, Blocked combustion air screen, Faulty gas control valve lockout

How to Fix / Troubleshooting

Safety first: Treat this as a potential flammable vapor event. Remove ignition sources and ventilate the area.

  • Step 1 – Remove vapor sources: Relocate gasoline, paint thinners, and other flammables away from the heater.
  • Step 2 – Clean air intake screen: Vacuum dust and lint from the base of the heater and combustion air openings.
  • Step 3 – Attempt reset per label: Follow the Ruud lighting and reset instructions on the heater. Some models require a specific sequence to clear lockout.
  • Step 4 – Replace FVS: If lockout persists, replace the OEM Ruud flammable vapor sensor as described in the FVS procedure.

If the status light pattern remains after sensor replacement, the gas control valve/thermostat may need replacement by a professional.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Flammable Vapor Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements