F22
Saunier Duval
Low water pressure / dry fire protection
F22 displayed, no ignition, often after water supply interruption
Advertisements
Possible Causes
Insufficient inlet water pressure, Blocked inlet filter, Air lock in system, Faulty water pressure switch (if fitted)
How to Fix / Troubleshooting
Safety first: Turn off power before opening any water connections.
Steps:
- Check water supply: Ensure the main water valve is fully open and that cold water is available at other taps.
- Clean inlet filter: Remove and clean the filter on the cold water inlet to the heater.
- Bleed air: Open hot taps to purge air from the system.
- Pressure switch: On models with a water pressure switch, check wiring and replace the switch if it does not close at normal pressure.
Warning: Do not operate the heater without water. This can destroy the heat exchanger.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Inlet Filter
Check Price on Amazon
We may earn a commission from links on this page.