F02
State
Temperature Sensor / Thermistor Error (Electric)
State electric water heater displays F02; water may be too hot or not hot enough.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed tank thermistor, Loose sensor connection to control, Control board sensor circuit fault
How to Fix / Troubleshooting
Safety: Turn off power at the breaker.
- Locate sensor: On electronic models, find the thermistor inserted into a well on the tank.
- Inspect and reseat: Ensure the sensor is fully inserted and the connector is secure.
- Test sensor: Measure resistance and compare to the State chart. Replace if out of spec.
- Control replacement: If a known-good sensor still yields F02, replace the electronic control.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Tank Thermistor
Check Price on Amazon