E03
Stiebel Eltron
Inlet Temperature Sensor (NTC) Fault
Stiebel Eltron tankless heater shows E03 and shuts down; water may briefly get hot then unit stops.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective inlet NTC sensor, Loose sensor clip on inlet pipe, Broken or pinched sensor wiring, Moisture intrusion at sensor connector
How to Fix / Troubleshooting
Safety: Switch off the circuit breaker and close the cold water supply before opening the unit.
- Access the inlet NTC: Remove the front cover. The inlet sensor is mounted on or near the cold water inlet pipe.
- Check mounting and cleanliness: Ensure the sensor is firmly attached to the pipe and not hanging loose. Clean any scale or corrosion from the contact area so the sensor can read accurately.
- Inspect wiring: Follow the sensor wires to the control board. Confirm the connector is fully seated and that there are no cuts or burn marks on the insulation.
- Resistance check (optional): With power off, disconnect the sensor and measure its resistance. Compare to the manufacturer’s NTC curve. Replace the sensor if readings are far outside spec or open/shorted.
- Reassemble and reset: Reconnect everything, restore water and power, and clear the error by cycling power. If E03 reappears, replace the inlet NTC sensor. Persistent errors after sensor replacement may indicate a faulty control board.