Stiebel Eltron
Intermittent Activation Failure
Water heater occasionally fails to start when a tap is opened, but works again after closing and reopening the tap.
Advertisements
Possible Causes
Marginal flow at activation threshold, Sticky flow sensor turbine, Partially clogged inlet filter, Air pockets in plumbing
How to Fix / Troubleshooting
Safety: Turn off power before opening the unit.
- Increase flow for testing: Fully open the hot tap and avoid mixing with cold to ensure maximum flow.
- Clean inlet filter: Remove and clean the inlet filter screen to reduce restriction.
- Clean flow sensor: Inspect and clean the flow sensor turbine and housing to ensure smooth rotation.
- Purge air: Open multiple hot taps to purge any trapped air from the system.
- Monitor: If intermittent failures continue, the flow sensor may need replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Inlet Filter / Flow Sensor Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements