103
Takagi
Insufficient Circulation / Heat Exchanger Overheat (Scale Buildup)
Takagi unit shuts down with error 103; water temperature may fluctuate before shutdown.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Lime scale buildup in primary heat exchanger, Partially closed hot water isolation valve, Clogged inlet water filter, Flow sensor partially blocked
How to Fix / Troubleshooting
Safety first: Turn OFF power and gas. Allow the heater to cool. Close the cold and hot isolation valves before disconnecting any plumbing. Wear gloves and eye protection when handling descaling chemicals.
Steps:
- 1. Check inlet water filter: Close the cold water isolation valve. Remove the cold inlet filter screen (usually at the cold inlet connection). Rinse under running water and brush off debris. Reinstall and open the valve.
- 2. Verify isolation valves: Ensure both hot and cold isolation valves to the heater are fully open during normal operation.
- 3. Descale the heat exchanger:
- Connect a tankless water heater flush kit (pump, hoses, and bucket) to the service ports on the hot and cold lines.
- Fill the bucket with white vinegar or a manufacturer-approved descaling solution.
- Open the service valves and run the pump to circulate solution through the heater for 45–60 minutes.
- After flushing, drain the solution, then flush with clean water for 5–10 minutes.
- 4. Inspect flow sensor: With water off and unit cool, remove the flow sensor assembly (usually on the cold inlet side). Check for debris or scale on the turbine/impeller. Clean gently and reinstall.
- 5. Restore service: Open all valves, restore power and gas, and test hot water. If error 103 returns, the heat exchanger may be severely scaled or damaged and may require replacement by a technician.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Primary Heat Exchanger
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements