441
Takagi
Flow Sensor Failure
Error 441 appears; unit shuts down or will not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck or scaled flow sensor turbine, Failed flow sensor, Debris in cold water inlet, Damaged flow sensor wiring
How to Fix / Troubleshooting
Safety first: Turn OFF power and gas. Close the cold and hot isolation valves and relieve water pressure before removing any water components.
Steps:
- 1. Clean inlet filter: Remove and clean the cold water inlet filter screen to remove debris that could affect the flow sensor.
- 2. Remove flow sensor: With water isolated and pressure relieved, remove the flow sensor assembly from the cold inlet side.
- 3. Inspect and clean: Check the turbine/impeller for scale or debris. Clean gently with a soft brush. Ensure it spins freely.
- 4. Check wiring: Inspect the flow sensor cable and connector for damage. Reseat the connector at the PCB.
- 5. Replace if necessary: If the sensor is damaged or still reports error 441 after cleaning, replace it with a genuine Takagi flow sensor.
- 6. Restore service: Reassemble, open valves, restore power and gas, and test hot water flow.