511
Takagi Gas Solenoid Valve Circuit Error

Error 511 displayed; unit does not ignite.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted gas solenoid coil, Damaged wiring harness to gas valve, Faulty main PCB driver circuit

How to Fix / Troubleshooting

Safety first: Turn OFF gas and power. Gas valve electrical testing should be done by a qualified technician.

Steps:

  • 1. Visual inspection: Check the gas valve and its wiring harness for visible damage, burn marks, or loose connectors.
  • 2. Reseat connectors: Firmly reconnect the gas valve plug at the valve and PCB.
  • 3. Professional testing: If the error remains, a technician should measure coil resistance and verify PCB output. Replacement of the gas valve assembly or PCB may be required.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Gas Valve Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements