761
Takagi Recirculation Pump Control Error

Takagi controller shows error 761 on a recirculation-capable model.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected or failed recirculation pump, Incorrect pump wiring, Overloaded pump circuit, Faulty PCB pump driver

How to Fix / Troubleshooting

Safety first: Turn OFF power and close isolation valves to the recirculation loop if present.

Steps:

  • 1. Check pump power: Ensure the recirculation pump is properly connected to the heater’s pump terminals or external power source as specified by Takagi.
  • 2. Inspect pump wiring: Look for loose or damaged wires at the pump and heater.
  • 3. Verify pump operation: With power restored (and observing safety), feel or listen for pump operation when recirculation is called. If the pump is seized or noisy, it may need replacement.
  • 4. Professional service: If wiring and pump are good but error 761 persists, the heater’s control board pump circuit may be faulty and should be replaced by a technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Recirculation Pump
Check Price on Amazon