Takagi
Short Cycling / Low Flow Operation
Intermittent hot water; Takagi unit cycles on and off rapidly, causing temperature swings.
Advertisements
Possible Causes
Flow rate below minimum activation threshold, Partially clogged aerators or showerheads, Oversized heater for single low-flow fixture, Misadjusted flow control valve
How to Fix / Troubleshooting
Safety first: Water may be hot; avoid scalding when removing aerators or showerheads.
Steps:
- 1. Increase flow: Open the hot water tap further or open an additional hot fixture to see if the unit stabilizes.
- 2. Clean aerators and showerheads: Remove and clean debris and scale from faucet aerators and showerheads to restore proper flow.
- 3. Check inlet filter: Clean the cold water inlet filter screen on the Takagi unit to improve flow.
- 4. Adjust temperature setting: Lower the set temperature on the remote. This can reduce cycling by requiring less modulation at low flows.
- 5. Professional evaluation: If short cycling persists, a technician should check the flow sensor, flow adjustment valve, and system design (e.g., recirculation, mixing valves).
Advertisements
Repair Difficulty
Easy
2/5
Advertisements