Takagi Short Cycling / Low Flow Operation

Intermittent hot water; Takagi unit cycles on and off rapidly, causing temperature swings.

Advertisements

Possible Causes

Flow rate below minimum activation threshold, Partially clogged aerators or showerheads, Oversized heater for single low-flow fixture, Misadjusted flow control valve

How to Fix / Troubleshooting

Safety first: Water may be hot; avoid scalding when removing aerators or showerheads.

Steps:

  • 1. Increase flow: Open the hot water tap further or open an additional hot fixture to see if the unit stabilizes.
  • 2. Clean aerators and showerheads: Remove and clean debris and scale from faucet aerators and showerheads to restore proper flow.
  • 3. Check inlet filter: Clean the cold water inlet filter screen on the Takagi unit to improve flow.
  • 4. Adjust temperature setting: Lower the set temperature on the remote. This can reduce cycling by requiring less modulation at low flows.
  • 5. Professional evaluation: If short cycling persists, a technician should check the flow sensor, flow adjustment valve, and system design (e.g., recirculation, mixing valves).
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Flow Sensor
Check Price on Amazon