Takagi Minimum Flow Activation Issue

Takagi water heater does not start when a single low-flow faucet (e.g., modern lavatory) is opened.

Advertisements

Possible Causes

Flow below heater’s minimum activation rate, Partially clogged flow sensor or inlet filter, Low inlet water pressure, Oversized mixing valve reducing flow through heater

How to Fix / Troubleshooting

Safety first: Water may be hot; use caution when adjusting fixtures.

Steps:

  • 1. Increase flow: Open the faucet further or open a second hot tap to see if the heater starts.
  • 2. Clean inlet filter and aerators: Remove debris from the cold inlet filter and faucet aerators to improve flow.
  • 3. Check flow sensor: With water off and pressure relieved, remove and clean the flow sensor turbine.
  • 4. Adjust or bypass mixing valve: If a mixing valve is installed, it may be throttling flow. Have a plumber adjust or reconfigure it to maintain sufficient flow through the heater.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Flow Sensor
Check Price on Amazon

We may earn a commission from links on this page.