Takagi
Minimum Flow Activation Issue
Takagi water heater does not start when a single low-flow faucet (e.g., modern lavatory) is opened.
Advertisements
Possible Causes
Flow below heater’s minimum activation rate, Partially clogged flow sensor or inlet filter, Low inlet water pressure, Oversized mixing valve reducing flow through heater
How to Fix / Troubleshooting
Safety first: Water may be hot; use caution when adjusting fixtures.
Steps:
- 1. Increase flow: Open the faucet further or open a second hot tap to see if the heater starts.
- 2. Clean inlet filter and aerators: Remove debris from the cold inlet filter and faucet aerators to improve flow.
- 3. Check flow sensor: With water off and pressure relieved, remove and clean the flow sensor turbine.
- 4. Adjust or bypass mixing valve: If a mixing valve is installed, it may be throttling flow. Have a plumber adjust or reconfigure it to maintain sufficient flow through the heater.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements