E09
Tesy Calibration / Temperature Control Error

Tesy heater shows E09; water does not heat to set temperature or overshoots significantly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect sensor calibration in control board, partially failing NTC sensor, firmware bug, control board analog-to-digital converter fault

How to Fix / Troubleshooting

Safety first: Disconnect power and allow the unit to cool if it has overheated.

Steps:

  • Verify actual water temperature: Draw hot water and measure with a reliable thermometer. Compare with the displayed temperature.
  • Check NTC sensors: Measure resistance of the main and outlet NTC sensors at a known temperature (e.g., room temperature). Compare to manufacturer’s resistance table if available. Replace any sensor with abnormal readings.
  • Factory reset (if supported): Some Tesy models allow a factory reset via button combination. Perform the reset according to the user manual to clear calibration errors.
  • Firmware update: If the model supports service firmware updates (via service port), have an authorized service center reflash the firmware.
  • Replace control board: If sensors are good and reset does not help, replace the electronic control board to restore proper temperature regulation.

Warning: Do not continue using the heater if it overheats water beyond safe limits; scalding risk is significant.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Electronic Control Board