Possible Causes

Undersized water heater or indirect tank, Scaled tank coil or plate exchanger, Low gas input, Incorrect priority settings

How to Fix / Troubleshooting

Safety: Avoid raising temperature excessively to compensate for capacity issues.

  • 1. Compare demand to capacity: Estimate your hot water usage (showers, appliances) and compare to the Triangle Tube unit's rated output. Heavy simultaneous use may exceed capacity.
  • 2. Check DHW priority: In the control menu, ensure DHW priority is enabled so the boiler focuses on reheating the tank when needed.
  • 3. Descale DHW coil/plate: Have a technician flush the indirect tank coil or combi plate heat exchanger to restore heat transfer.
  • 4. Verify gas input: A gas technician should confirm that inlet pressure and orifice sizing match the rating plate.
  • 5. Consider upgrades: If usage has increased (e.g., added bathrooms), you may need a larger indirect tank or higher-capacity Triangle Tube unit.